Saturday, 3 October 2015

How to show more than 999+ in RTC Cue




Issue: If we have more than 999 Sales Orders – Open then the RTC cue will show 999+ instead of exact number.




Solution: 
1.    Go to particular activities page. (SO Processor Activities in my case)
2.    Select the field which is having issue (<Sales Orders - Open>)
3.    Click Properties from View or shortcut Shift + F4
4.    Select property Image
5.    Now it is set to <Stack>
6.    Change it to None
7.    Save the page and restart the RTC